Specification UB104S01
e600) 10.4" SVGA (800h x S ta Color TFT a .D w w w
w w .D at Sh a et e 4U
t e
U 4
.c
m o
.
om c
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 info@datamodul.com - www.datamodul.com
w
Record of Revision
Version Revise Date Page Content
1
26/Apr./2000
14
First draft.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
A. Physical specification












B. Electrical specifications













Contents:
1. Pin assignment












2. Absolute maximum ratings












3. Electrical characteristics











a. Typical operating conditions









b. Display color v.s. input data signals
PAGE
...











c. Input signal timing













d. Display position










e. Backlight driving conditions













C. Optical specifications













D. Reliability test items














E. Display quality













F. Handling precaution














G. Packing form















Appendix:
Fig.1 LCM outline dimensions
........................






Fig.2 Timing chart















:
1/14
P15 P14 P13 P12 P12 P11 P10 P9 P8 P7 P6 P5 P5 P4 P3 P3 P2
PAGE
:
2/14
A. Physical specifications
NO. 1 2 3 4 5 6 7 Item
Specification 800(H) 600(V) 158.4(V)
Remark
Display resolution(pixel) Active area(mm) Screen size(inch) Pixel pitch(mm) Color configuration Overall dimension(mm) Weight(g)
211.2(H)
10.4(Diagonal)
0.264(H)
0.264(V)
R. G. B. Vertical stripe

236(W)
174.3(H)
5.7(D) ( Max )
Note 1
285
10
Note 1: Refer to Fig. 1.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
:
3/14
B. Electrical specifications
1.Pin assignment (1).Input signal interface
Pin no 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Symbol VCC VCC GND GND RxIN0RxIN0+ GND RxIN1RxIN1+ GND RxIN2RxIN2+ GND CKINCKIN+ GND NC NC GND GND Ground No Connection No Connection Ground Ground Ground LVDS receiver signal clock Ground LVDS receiver signal channel 2 Ground LVDS receiver signal channel 1 Function +3.3 V power supply +3.3 V power supply Ground Ground LVDS receiver signal channel 0 Etc.
CN1 (20P) connector : HRS DF 19K-20P-1H
or Compatible
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
(2) LVDS transmitter/receiver signal mapping
Symbol TxIN0 TxIN1 TxIN2 TxIN3 TxIN4 TxIN5 TxIN6 TxIN7 TxIN8 TxIN9 TxIN10 TxIN11 TxIN12 TxIN13 TxIN14 TxIN15 TxIN16 TxIN17 TxIN18 TxIN19 TxIN20 TxCLKIN R0 R1 R2 R3 R4 R5 G0 G1 G2 G3 G4 G5 B0 B1 B2 B3 B4 B5 Hs Vs DE CLK Red data (LSB) Red data Red data Red data Red data Red data (MSB) Green data (LSB) Green data Green data Green data Green data Green data (MSB) Blue data (LSB) Blue data Blue data Blue data Blue data Blue data (MSB) Horizontal sync Vertical sync Data enable Clock Function
:
4/14
6 bit red display data
6 bit green display data
6 bits blue display data
Dot clock
2. Absolute maximum ratings
Parameter Power voltage Input signal voltage Operating temperature Storage temperature Symbol VCC VLH Top TST Min. -0.3 -0.3 -10 -20 Values Max. 4 VCC+0.3 +60
(GND = 0 V)
Unit VDC VDC
Remark At 25 At 25 Note 1 Note 1
+70
Note 1:The relative humidity must not exceed 90% non-condensing at temperatures of 40 or less. At temperatures greater than 40 , the wet bulb temperature must not exceed 39 . When operate at low temperatures, the brightness of CCFL will drop and the life time of CCFL will be reduced. Note 2:The unit should not be exposed to corrosive chemicals.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
3. Electrical characteristics a. Typical operating conditions
Item Power supply voltage Input voltage Current consumption Inrush current Internal logic Low voltage High voltage Power ripple voltage Symbol VCC IA IB I RUSH VIL VIH VRP 0 0.7VCC Min. 3.0 Typ. 3.3 310 330 1500 0.3 VCC VCC 100 Max. 3.6
:
5/14
Unit V mArms mArms mApeak
Remark
Note 1 Note 2
mVp-p
Note 1:Effective value (mArms) at VCC = 3.3 V/25| .
IA IB Black (0) 64 Gray (7) 64 Vertical stripe line
White 64 Grayscale
Black
Note 2: Refer to the following power-on condition.
90%
Vcc 10% Ton=470 s
Sequence of Power-on/off and signal-on/off
T3 T4 T2 0
(c)
T1 T5
T2 70msec
(c)
300msec
(c)
Input signal
300msec
(c)
T5
10msec
Apply the lamp voltage within the LCD operating range. When the backlight turns on before the LCD operation or the LCD turns off before the backlight turns off, the display may momentaily become abnormal.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Power
30ms
T1 70msec
T3 T4
PAGE
Caution
:
6/14
The above on/off sequence should be applied to avoid abnormal function in the display. In case of handling: Make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. b. Display color v.s. input data signals
Display colors Black Blue Red Magenta Green Cyan Yellow White Black Dark
Data signal (0 : Low level, 1: High level) R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 1 0 0 1 1 0 0 1 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0
Basic colors
Red grayscale
bright 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Red Black Dark
Green grayscale
bright 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0
Green Black Dark
Blue grayscale
bright 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1
Blue
Note : Each basic color can be displayed in 64 gray scales using the 6 bit data signals. By combining the 18-bit data signals(R,G,B), the 262, 144 colors can be achieved on the display.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com

PAGE
c. Input signal timing Timing diagrams of input signal are shown in Fig 2. (1). Timing characteristics of input signals (a) DE mode
Item Clock frequency Horizontal blanking Vertical blanking Symbol Fck Thb1 Tvb1 Min. 38 50 10 Typ. 40 256 28 Max. 42 500 150
:
7/14
Unit MHz Clk Th
Remark
(b) HV mode
Item Clock frequency Hsync period Hsync pulse width Hsync front porch Hsync back porch Hsync blanking Vsync period Vsync pulse width Vsync front porch Vsync blanking Hsync/Vsync phase shift Symbol Fck Th Thw Thf Thb Thb1 Tv Tvw Tvf Tvb1 Tvpd Min. 38 850 10 15 10 50 610 1 0 10 2 Typ. 40 1056 128 40 88 256 628 4 1 28 320 Max. 48 1300 500 750 150 Unit MHz Clk Clk Clk Clk Clk Th Th Th Th Clk Remark
Item
Symbol
Value 218
Unit Clk
Description After falling edge of Hsync, counting 218clk, then getting valid data from 219th clk's data. After falling edge of Vsync, counting 25 Th, then getting 26 th Th's data.
Horizontal display start The
Vertical display start
Tve
25
Th
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
(2). The timing condition of LVDS
Item The differential level The common mode input voltage The input setup time The input hold time
:
8/14
Symbol
Min. 0.1 VID 2 500 500

Typ.
Max. 0.6 2.4 VID 2
Unit V V ps ps
VID VIC tsu1 th1
VID
VID = VIAP - VIAM
VIAP
VIAM
tsu1 th1
An 7 LCK
d.Display position
D( 1,1 ) D( 1,2 ) . . . D( 1,Y ) . . . D( 1,599 ) D( 1,600 ) D( 2,1 ) D( 2,2 ) ...... ...... ...... D( 2,Y ) ...... ...... D( 2,599 ) D( 2,600 ) ...... ...... D( X,1 ) D( X,2 ) . . . D( X,Y ) . . . D( X,599 ) D( X,600 ) ...... ...... ...... ...... ...... ...... ...... D( 799,1 ) D( 799,2 ) . . . D( 799,Y ) . . . D( 800,1 ) D( 800,2 ) . . . D( 800,Y ) . . .
D( 799,599) D( 800,599 ) D( 799,600) D( 800,600)
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
e.Backlight driving conditions
Parameter Lamp voltage Lamp current Power consumption Lamp starting voltage Frequency Lamp life time Symbol VL IL PL VS FL LL 10000 Min. Typ. 488 4.3 2.1 TBD TBD 60 Max. -
:
9/14
Unit Vrms mArms W Vrms KHZ Hr
Remark Note 1 Note 1 Note 2 T=0 T=25 Note 3 Note 1, 4
Note 1: T= 25 , IL = 4.3 Note 2: Inverter should be designed with the characteristic of lamp. When you are designing the inverter, the output voltage of the inverter should comply with the following conditions. (1).The area under the positive and negative cycles of the waveform of the lamp current and lamp voltage should be area symmetric(the symmetric ratio should be larger than 90%). (2).There should not be any spikes in the waveform. (3).The waveform should be sine wave as possible. (4).Lamp current should not exceed the maximum value within the operating temperature (It is prohibited to over the maximum lamp current even if operated in the non-guaranteed temperature). When lamp current over the maximum value for a long time, it may cause fire. Therefore, it is recommend that the inverter should have the current limiter circuit. Note 3: Lamp frequency may produce interference with horizontal synchronous frequency and this may cause line flow on the display. Therefore lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference. In case using the inverter by PWM control, PWM frequency may interference with frame frequency. We suggest that PWM frequency is same as frame frequency. Note 4: Brightness to be decrease to the 50% of the initial value. Note 5: CN2 connector(backlight): JST BHSR-02VS-1 Mating connector: JST SM02B-BHSS-1-TB
Pin no. 1 2 Symbol H L Function CCFL power supply(H.V.) CCFL power supply(GND) Remark Cable color: Pink Cable color: White
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
:
10/14
C. Optical specifications ( Note 1, Note 2, Note 3 )
Item Response time Rising time Falling time Contrast ratio Viewing angle Top Bottom Left Right Brightness Color chromaticity(CIE) CR
Symbol
Condition
Specification Min. 150 10 30 40 40 130 Typ. 20 30 250 15 35 45 45 150 (0.31) (0.33) Max. 40 50 1.8
Unit
Remark
Wx Rx Ry Gx Gy Bx By

Wy
White uniformity
W
Note 1: Ambient temperature = 25 . Note 2: To be measured in dark room after backlight warm up 30 minutes. Note 3: To be measured with a viewing cone of 1 by Topcon luminance meter BM-5A. Note 4: Definition of response time: The output signals of photodetector are measured when the input signals are changed from "Black" to "White" (falling time) and from "White" to "Black" (rising time), respectively. The response time interval between the 10% and 90% of amplitudes. Refer to figure as below.
"White"
100% 90%
Signal(Relative value)
10% 0%
Tr
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
YL
CR
Tr Tf
=0 =0
ms
Note 4 Note 5
10
deg.
Note 8
=0 =0
nit
Note 6,7
Note 9
"Black"
"White"
Tf
PAGE
Note 5. Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio (CR)=
:
11/14
Photodetector output when LCD is at "White" state Photodetector output when LCD is at "Black" state
Note 6: Definition of brightness: This shall be measured at center of the screen. Note 7: Driving conditions for CCFL : IL=4.3 mA,60KHz Frequency Note 8: Definition of viewing angle:
Note 9: Definition of white uniformity: White uniformity is defined as the following with thirteen measurements (A-M)
w =
Maximum Luminance of thirteen points (brightness) Minimum Luninance of thirteen points (brightness)
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
:
12/14
D. Reliability test items(Note 1)
Test tem High temperature storage Test Condition 70 , 240Hrs judgement Remark 1.Function OK Note 1, 2 2.No serious image quality degradation 1.Function OK Note 1, 2 2.No serious image quality degradation Note 1, 2 1.Function OK 2.No serious image quality degradation 1.Function OK Note 1, 2 2.No serious image quality degradation 1.Function OK Note 1, 2 2.No serious image quality degradation Note 1, 2 1.Function OK 2.No serious image quality degradation
Low temperature storage
-20 , 240Hrs
High temperature & high humidity operation
40 , 90%RH, 240Hrs (No condensation)
High temperature operation
60 , 240Hrs
Low temperature operation
-10 , 240Hrs
Temperature cycling (non-operation) Electrostatic discharge (non-operation) Vibration (non-operation) Mechanical shock (non-operation)
-20 ~70 1H, 10mins, 1H, 5cycles
150 pF,150 ,10kV,1 second, 9 position 1.Function OK on the panel, 10 times each place 2.No serious image quality degradation Sweep:1G, 10HZ ~ 500HZ ~ 10HZ /2.5min 1.Function OK Note 1, 2 2 hour for each direction X, Y, Z 2.No serious image (6 Hrs in total) quality degradation

(50G, 11ms),
X,
Y,
Z
once for each direction
1.Function OK 2.No serious image quality degradtion
Note 1, 2
Note 1: Evaluation should be tested after storage at room temperature for one hour. Note 2: There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition.
E. Display quality
The display quality of the color TFT-LCD module should be in compliance with the Unipac's OQC inspection standard.
F. Handling precaution
The Handling of the TFT-LCD should be in compliance with the Unipac's handling principle standard.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
PAGE
:
13/14
G. Packing form :TBD
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Fig.1 LCM outline dimensions
Vs
Tvw Th Tve
Invalid X,1 X,2 X,3 X,599 X,600
Tv
Hs
Tvf
Invalid
Tvf Tvbl Thb Tvd
RGB
Thw
X,599 X,600
DE
Hs
Th
CLK
The
invalid 1,Y 2,Y 3,Y 799,Y 800,Y
Thf
Thf
invalid
RGB
Thbl Thd
800,Y
DE
(1 pixel / clock)
RGB,DE,Hs CLK VIH VIL VIH VIL
Vs
VIH
VIL
PAGE
Hs
Tvpd
VIH VIL
Tds,Tes,Ths Tdh,Teh,Thh
Tch
Tcl
:
14/14
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Fig.2 Timing chart


▲Up To Search▲   

 
Price & Availability of UB104S01V1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X